Article R4534-126
The provisions of this sub-section apply when work is carried out inside premises containing only low voltage A (LVA) electrical lines or installations within the meaning of Article R. 4534-107.
20+ full codes, 2,400+ articles translated and updated. Case law linked to every article. Read the actual text before you ask a lawyer about it — free, no login required.
20+
french codes
Fully translated
2,400+
articles in English
Updated regularly
480+
court rulings linked
Per article
Free
full access
No login required
Showing 4521–4530 of 58186 articles for “Art. Loi 2013-98 du 28-1-2013”
The provisions of this sub-section apply when work is carried out inside premises containing only low voltage A (LVA) electrical lines or installations within the meaning of Article R. 4534-107.
…by having or carrying out effective insulation by covering bare or insufficiently insulated live conductors and parts or parts likely to be brought into contact with them.
Once the employer has issued the work stoppage notice, he may only resume work if he is in possession of a new de-energisation certificate.
…recording number, when the time taken to transmit a written document would excessively increase the duration of the interruption to distribution.
Where it has been agreed to de-energise the line, pipe or electrical installation, whether underground or not, the employer shall ask the operator to de-energise the line, pipe or electrical installat…
When carrying out construction work involving the use of heavy prefabricated elements, the stability of each of these elements is ensured, as soon as they are in place, by appropriate rigid devices. R…
The provisions of this sub-section apply when work is carried out in the vicinity of electrical lines, pipes and installations: 1° Located outside premises and in the low-voltage A area (BTA), i.e. wh…
To determine the minimum distances to be observed in relation to normally energised bare conductive parts, account must be taken of: 1° All possible movements of the energised bare conductive parts of…
…nergising has been carried out; 3° Protects himself against the accidental re-energising of voltage during the work, preferably by locking the corresponding switching or isolating devices in the open…
Work cannot begin until the employer is in possession of the de-energisation certificate, written, dated and signed by the operator.
Avocate au Barreau de Paris
Toque #C2396
15+ Years In French Corporate Practice
English · French · Russian
Ready When You Are
A 20–30 minute call, in English, to scope the engagement. No obligation, no preliminary fee. You will leave the call with a clear view of what the work will cover and what it will cost.
20+ full codes and 2,400+ articles in English, with the key court rulings linked to every article — free to read.
Read MoreA lawyer-reviewed report explaining how the relevant articles apply to your situation, with case-law analysis and next steps.
Read MoreScope your matter with a Paris-Bar avocate — incorporation, contracts, disputes — handled bilingually, end to end.
Read More